Applications
Direct-to-chip is the center of gravity, but the same platform covers the rest of the thermal loop and extends into energy storage. What changes between them is not the architecture, it is which constraint dominates.
- Direct-to-chip
- Low flow per node but very little tolerance for particulate or leakage. Cleanliness of the fluid path and long unattended duty decide service life.
- Rack CDUs
- Tight envelope, acoustic limits that genuinely bind, and redundancy inside the rack. Serviceability without pulling the unit matters more than peak efficiency.
- Row CDUs
- Higher flow and head across multiple racks, with controls integration into the CDU’s own supervisory system and load-following behavior.
- Rear-door heat exchangers
- Retrofit constraints dominate. Existing facility power, existing piping, and whatever space the door leaves you.
- Facility water loops
- Continuous duty at the top of the range, with redundancy schemes and maintenance intervals set by facility policy.
- Immersion support
- Dielectric fluid compatibility and long submerged duty, where material selection in the wet path is the main engineering question.
- Battery and BESS thermal
- Wide ambient range, long idle periods punctuated by high demand, and safety requirements that make a sealed fluid path valuable on its own terms.
Beyond data centers
This is a pump platform, not a data center product. The same seal-less hydraulics, the same slotless motor, and the same integrated drive cover the whole 0.10 to 5.0 kW range, which is a wide swath of the pump world.
Data centers are where this pump line enters the market, because that is where the urgency is and where the design advantage matters most. It is not new ground for us: the team has worked in data center cooling since the early 2000s. Nor is it the ceiling. If it needs a pump in this size range the platform can be configured for it, and we intend to offer off-the-shelf models alongside custom work for equipment makers.
Other application areas
- Circulation and process
- Industrial equipment
- Battery and energy storage thermal
- Marine
- Agricultural
- Sump and transfer
- OEM private label
- Off-the-shelf models
Customer channels
Design-in engagements with the people building the loop, plus private label and supply agreements for OEMs putting their own badge on the assembly.
- Hyperscalers
- Colocation operators
- CDU OEMs
- Rack & server OEMs
- EPC & design-build
- ESS integrators
Not sure it fits
If your application is not on this list, the question is usually whether the duty point sits inside the range and whether the fluid is compatible with the wet path. Both are quick to answer.
Send the loop conditions listed under specifying and we will tell you either way.